Electronic Controlled Systems

VE6.3.4.1
Electronic Controlled Systems
Electronic Controlled Systems

This product is classified as a dangerous good and is not available for online purchase.

For ordering the dangerous good or other information please contact our customer service center.
This experiment/set up contains dangerous goods.
These are not available for online purchase.
You may order the experiment/set up without the dangerous goods.


For ordering the dangerous good or other information please contact our customer service center.
Email: webshopuk@ld-didactic.de
Telephone:+49 (0) 22 33 / 604 – 319
Go to contact form

˟

Request an offer

Thank you for your inquiry. We will get back to you as soon as possible.

˟

Description

System

The experiments are set up with experiment plates in profile frames. The controlled system or control circuit are activated with the Profi-CASSY and the relevant measurement values recorded.

Educational objectives

  • Get familiar with the basic principles of controllers
  • Setpoint and disturbance control
  • Handle analysis and simulation software

Function
The setup facilitates experiments on a wide variety of levels: ranging from the basics to university-level learning. It investigates the transfer components in the time range and the behaviour of the controlled systems formed by them. Digital adjusters for controller parameters and system time constants facilitate simple, intuitive operation of devices with higher precision. This allows for fast, reproducible, and targeted experimentation. Continuous and discontinuous controller designs are available to choose from. The Profi-CASSY interface is ideally equipped to support the use of graphic analysis methods (e.g. using the tangent method) and facilitates experiments with modern interface controllers and computer-aided control technology. For more in-depth experimentation and for simulations, it is recommended that you also use the WinFACT software.

 

The equipment set incorporates student experiments which can be carried out in a laboratory safely using safety extra-low voltage. Experiment instructions are contained in a manual in either printed or digital form.

Add-ons
The following sets are recommended for further learning:
E 6.3.4.2 Digital Controlling
E 6.3.4.3 Fuzzy Controlling

Topics

  • Setpoint and disturbance behaviour
  • Recording and analysing step responses
  • Output parameters of an open-path control
  • Time response of transfer components
  • Second order transfer component
  • Behaviour of the dead-time component
  • Time behaviour of the controllers
  • Controlling a system with startup time and dead time
  • Two-point control
  • Quasi-continuous control
  • Controlling an integral system
  • P/PI controlling of a first order system (pneumatic)
  • Integral control of a first order system (hydraulics)
  • Control of a second order system (speed)
  • Setpoint and disturbance behaviour
  • Recording and analysing step responses
  • Output parameters of an open-path control
  • Time response of transfer components
  • Second order transfer component
  • Behaviour of the dead-time component
  • Time behaviour of the controllers
  • Controlling a system with startup time and dead time
  • Two-point control
  • Quasi-continuous control
  • Controlling an integral system
  • P/PI controlling of a first order system (pneumatic)
  • Integral control of a first order system (hydraulics)
  • Control of a second order system (speed)

Components of equipment sets

1 73402  8  Reference variable generator LD
1 734011  4  Two position controller LD
1 734064N  8  PID digital controller net LD
2 734091 Digital Controlled System LD
1 7340891  8  Dead time element LD
1 7340951  8  2nd Order transfer element LD
1 524016S2  8  Profi-CASSY Starter 2 LD
1 72609  4  Panel frame T130, two-level LD
1 72686  4  Stabilised power supply unit ±15 V / 3 A LD
1 50059  8  Safety bridging plugs, black, set of 10 LD
1 500592  8  Safety bridging plugs with tap, black, set of 10 LD
1 56419DE  4  LIT-print: Control of Electronic Circuits, German LD
1 734501  4  WINFACT LD Starter (one computer) LD
1 734502  4  WINFACT LD Starter (site license) LD
3 500641  8  Safety experiment cable, 100 cm, red LD
3 500642  4  Safety experiment cable, 100 cm, blue LD
3 500644  8  Safety experiment cable, 100 cm, black LD
1 56419EN  4  * LIT-print: Control of Electronic Circuits LD
1 734504 * WINFACT LD Edition (one computer) LD
1 734505  4  WINFACT LD Edition (Site Licence) LD
1 additionally required: 1 PC with Windows 7 / 8.1 / 10 (x86 or x64)
Experiments are operated and evaluated with CASSY Lab 2 and WinFACT.

Articles marked with * are not essential, we do however recommend them to carry out the experiment.

Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM

Repair Service
You would like to register a repair? FORM

Europe
For European distributors, please visit: European distributors
Worldwide requests
Please contact us per email: sales@ld-didactic.de

 Click here for our contact form and postal address.

Contact Us